SLUUBY1B December 2020 – April 2022 BQ76942
Class | Subclass | Name | Type | Min | Max | Default | Unit |
---|---|---|---|---|---|---|---|
Protections | OCD3 | Threshold | I2 | –32768 | 0 | –4000 | userA |
Description: This parameter sets the Overcurrent in Discharge 3rd Tier Protection threshold. Units of reported current are configurable. This parameter uses the same units as reported current, so it is in units of user-amps.