SLUUBY2B September 2020 – May 2022 BQ76952
Class | Subclass | Name | Type | Min | Max | Default | Unit |
---|---|---|---|---|---|---|---|
Settings | Protection | Enabled Protections A | U1 | 0x00 | 0xFF | 0x88 | Hex |
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
SCD | OCD2 | OCD1 | OCC | COV | CUV | RSVD_0 | RSVD_0 |
Description: This bitfield enables or disables various protections. Protections which are enabled will set their corresponding Safety Status flags. Note that Settings:Protection:CHG FET Protections A and Settings:Protection:DSG FET Protections A must be appropriately configured to control the FET action taken when these faults are detected.
Bit | Field | Default | Description |
---|---|---|---|
7 | SCD | 1 | Short Circuit in Discharge Protection 0 = Disabled 1 = Enabled |
6 | OCD2 | 0 | Overcurrent in Discharge 2nd Tier Protection 0 = Disabled 1 = Enabled |
5 | OCD1 | 0 | Overcurrent in Discharge 1st Tier Protection 0 = Disabled 1 = Enabled |
4 | OCC | 0 | Overcurrent in Charge Protection 0 = Disabled 1 = Enabled |
3 | COV | 1 | Cell Overvoltage Protection 0 = Disabled 1 = Enabled |
2 | CUV | 0 | Cell Undervoltage Protection 0 = Disabled 1 = Enabled |