SLUUBY2B September 2020 – May 2022 BQ76952
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RSVD_0 | HWMX | VSSF | VREF | LFOF | RSVD_0 | RSVD_0 | RSVD_0 |
Description: Provides individual alert signals when enabled Permanent Fail alerts have triggered.
Bit | Field | Description |
---|---|---|
6 | HWMX | Hardware Mux Permanent Fail 0 = Alert is not triggered. 1 = Alert is triggered. |
5 | VSSF | Internal VSS Measurement Permanent Fail 0 = Alert is not triggered. 1 = Alert is triggered. |
4 | VREF | Internal Voltage Reference Permanent Fail 0 = Alert is not triggered. 1 = Alert is triggered. |
3 | LFOF | Internal LFO Permanent Fail 0 = Alert is not triggered. 1 = Alert is triggered. |