SLUUBY2B September 2020 – May 2022 BQ76952
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CUDEP | SOTF | RSVD_0 | SOT | SOCD | SOCC | SOV | SUV |
Description: Saved Permanent Failure Status A
Bit | Field | Description |
---|---|---|
7 | CUDEP | 0 = Copper Deposition Permanent Fail did not occur 1 = Copper Deposition Permanent Fail occurred |
6 | SOTF | 0 = Safety FET Overtemperature Permanent Fail did not occur 1 = Safety FET Overtemperature Permanent Fail occurred |
4 | SOT | 0 = Safety Cell Overtemperature Permanent Fail did not occur 1 = Safety Cell Overtemperature Permanent Fail occurred |
3 | SOCD | 0 = Safety Overcurrent in Discharge Permanent Fail did not occur 1 = Safety Overcurrent in Discharge Permanent Fail occurred |
2 | SOCC | 0 = Safety Overcurrent in Charge Permanent Fail did not occur 1 = Safety Overcurrent in Charge Permanent Fail occurred |
1 | SOV | 0 = Safety Cell Overvoltage Permanent Fail did not occur 1 = Safety Cell Overvoltage Permanent Fail occurred |
0 | SUV | 0 = Safety Cell Undervoltage Permanent Fail did not occur 1 = Safety Cell Undervoltage Permanent Fail occurred |