SLUUCA6 October 2021 BQ27Z746
Writes to this command are interchangeable with AltManufacturerAccess(). This command is provided to enable an easy way to verify the active MAC command while reading the MACData() returned by the MAC. The host may simply read from AltManufacturerAccess() to MACDataLength() with one block read. For a description of returned data values, see the AltManufacturerAccess() version of same command in Section 16.2.
I2C Cmd | Name | Access | Proto- col | Type | Min | Max | Default | Unit | ||
---|---|---|---|---|---|---|---|---|---|---|
SE | US | FA | ||||||||
0x3E/3F | AltManufacturerAccess() | R | R | R | Word | — | — | — | — | — |