SLUUCH2 March 2021 BQ40Z50-R2
This command sets the System Resistance value of the system serial resistance along the path from the battery to the system power converter input that includes FETs, traces, sense resistors, and so on.
SBS Cmd | Name | Access | Protocol | Type | Min | Max | Default | Unit | ||
---|---|---|---|---|---|---|---|---|---|---|
SE | US | FA | ||||||||
0x5C | TurboSysR() | R/W | R/W | R/W | Word | I2 | 0 | 32767 | mΩ |