SLUUCH2 March 2021 BQ40Z50-R2
To reduce power consumption, the device can be sent to SHUTDOWN mode before shipping. After sending this command, the OperationStatus()[SDM] = 1, an internal counter will start, and the CHG and DSG FETs will be turned off when the counter reaches Ship FET Off Time. When the counter reaches
Ship Delay
time, the device will enter SHUTDOWN mode if no charger present is detected.
If the device is SEALED, this feature requires the command to be sent twice in a row within 4 seconds (for safety purposes). If the device is in UNSEALED or FULL ACCESS mode, sending the command the second time will cancel the delay and enter shutdown immediately.
To wake up the device, a voltage > Charger Present Threshold must apply to the PACK pin. The BQ40Z50-R4 device will power up and a full reset is applied.