Alternatively, sending a manual FET control (MFC) sequence using the steps below also puts the gauge to the EMERGENCY FET SHUTDOWN state. This entry method applies to [NR] = 0 and [NR] = 1.
Send word 0x27060x270C to ManufacturerAccess() (0x00) to enable the MFC.
Within 4 s, send word 0x043D to ManufacturerAccess() (0x00) to turn off CHG and DSG FETs.
The CHG and DSG FETs will be off after Manual FET Control Delay.