SLUUCO9A April 2023 – November 2023 BQ28Z620
The device has a hardware-based short circuit in discharge protection with adjustable current and delay.
Status | Condition | Action |
---|---|---|
Normal | Current() > (ASCD:Threshold 1[2:0]/RSENSE)
AND Current() > (ASCD:Threshold 2[2:0]/RSENSE) | SafetyAlert()[ASCD] = 0 |
Trip | Current() continuous ≤ (ASCD:Threshold
1[2:0]/RSENSE) for ASCD:Threshold
1[7:4] duration OR Current() continuous ≤ (ASCD:Threshold 2[2:0]/RSENSE) for ASCD:Threshold 2[7:4] duration | SafetyStatus()[ASCD] = 1 OperationStatus()[XDSG] = 1 |
Recovery | SafetyStatus()[ASCD] = 1 for ASCD:Recovery time | SafetyStatus()[ASCD] = 0 OperationStatus()[XDSG] = 0 |