Table 18-1 Overload in Discharge Protection Threshold
(Settings:AFE:AFE Protection Control [RSNS] = 0)OLD Threshold ([RSNS] = 0)(1) |
---|
Setting | Threshold | Setting | Threshold |
---|
0x00 | –4.15
mV | 0x08 | –15.27
mV |
0x01 | –5.54
mV | 0x09 | –16.66
mV |
0x02 | –6.93
mV | 0x0A | –18.05
mV |
0x03 | –8.32
mV | 0x0B | –19.44
mV |
0x04 | –9.71
mV | 0x0C | –20.83
mV |
0x05 | –11.10
mV | 0x0D | –22.22
mV |
0x06 | –12.49
mV | 0x0E | –23.61
mV |
0x07 | –13.88
mV | 0x0F | –25.00
mV |
(1) The data flash setting
Protection:AOLD
Threshold[3:0] sets the voltage threshold.
Table 18-2 Overload in Discharge Protection Threshold
(Settings:AFE:AFE Protection Control [RSNS] = 1)OLD Threshold ([RSNS] = 1)(1) |
---|
Setting | Threshold | Setting | Threshold |
---|
0x00 | –16.60 mV | 0x08 | –61.08 mV |
0x01 | –22.16 mV | 0x09 | –66.64 mV |
0x02 | –27.72 mV | 0x0A | –72.20 mV |
0x03 | –33.28 mV | 0x0B | –77.76 mV |
0x04 | –38.84 mV | 0x0C | –83.32 mV |
0x05 | –44.40 mV | 0x0D | –88.88 mV |
0x06 | –49.96 mV | 0x0E | –94.44 mV |
0x07 | –55.52 mV | 0x0F | –100.00 mV |
(1) The data flash setting
Protection:AOLD
Threshold[3:0] sets the voltage threshold.
Table 18-3 Overload in Discharge Protection DelaySetting(1) | Time | Setting | Time | Setting | Time | Setting | Time |
---|
0x00 | 1 ms | 0x04 | 9 ms | 0x08 | 17 ms | 0x0C | 25 ms |
0x01 | 3 ms | 0x05 | 11 ms | 0x09 | 19 ms | 0x0D | 27 ms |
0x02 | 5 ms | 0x06 | 13 ms | 0x0A | 21 ms | 0x0E | 29 ms |
0x03 | 7 ms | 0x07 | 15 ms | 0x0B | 23 ms | 0x0F | 31 ms |
(1) The data flash setting
Protection:AOLD
Threshold[7:4] sets the delay time.