SLUUCO9A April 2023 – November 2023 BQ28Z620
The device has an undertemperature protection for cells in charge direction.
Status | Condition | Action |
---|---|---|
Normal | Temperatures() > UTC:Threshold OR not charging | SafetyAlert()[UTC] = 0 |
Alert | Temperatures() ≤ UTC:Threshold AND charging | SafetyAlert()[UTC] = 1 |
Trip | Temperatures() ≤ UTC:Threshold AND charging for UTC:Delay duration | SafetyAlert()[UTC] = 0 SafetyStatus()[UTC] = 1 OperationStatus()[XCHG] = 1 |
Recovery | SafetyStatus()[UTC] AND Temperatures() ≥ UTC:Recovery | SafetyStatus()[UTC] = 0 OperationStatus()[XCHG] = 0 |