SLUUCO9A April 2023 – November 2023 BQ28Z620
All calibration steps that require accessing data on MACData() must begin read operations starting at MACSubcmd() to ensure the data portion of the block is properly refreshed per the intended MACSubcmd() subcommand (in this case 0xF081 or 0xF082). The first two bytes returned are the MACSubcmd() subcommand followed by the counter, status, and raw ADC values, as shown in Table 12-1.