SLUUCO9A April 2023 – November 2023 BQ28Z620
The device can permanently disable the battery pack in case of a voltage difference between the cells in a stack while active.
Status | Condition | Action |
---|---|---|
Normal | CellVoltage0..13() < VIMA:Check Voltage OR |Current()| <VIMA:Check Current OR Δ(CellVoltage0..1()) < VIMA:Delta Threshold | PFAlert()[VIMA] = 0 |
Alert | Any(CellVoltage0..1()) ≥ VIMA:Check Voltage AND |Current()| >VIMA:Check Current AND Δ(CellVoltage0..1()) ≥ VIMA:Delta Threshold | PFAlert()[VIMA] = 1 |
Trip | Any(CellVoltage0..1()) ≥ VIMA:Check Voltage AND |Current()| >VIMA:Check Current AND Δ(CellVoltage0..1()) ≥ VIMA:Delta Threshold for VIMA:Delay | PFAlert()[VIMA] = 0 PFStatus()[VIMA] = 1 BatteryStatus()[TCA] = 1 BatteryStatus()[TDA] = 1 |