SLUUCP8 June 2024 BQ41Z50
The command is used to access Date and Time information from the gauge. It can work under SEALED, UNSEALED, and FULL ACCESS mode.
By sending RTC_Access() command, RTC information will be returned in the format of AABBCCddDDEEFFGGHH.Value | Description |
---|---|
AA | Day of the week |
BB | Day of the month |
CC | Month |
DDdd | Year |
EE | Second |
FF | Minute |
GG | Hour |
HH | 2's Complements Check Sum of all the above bytes |