SLUUCP8 June 2024 BQ41Z50
The BQ41Z50 device has an overtemperature protection for cells under charge.
Status | Condition | Action |
---|---|---|
Normal | Max Cell Temp TS1..4 < OTC:Threshold OR not charging | SafetyAlert()[OTC] = 0 |
Alert | Max Cell Temp TS1..4 ≥ OTC:Threshold AND charging | SafetyAlert()[OTC] = 1 BatteryStatus()[TCA] = 1 |
Trip | Max Cell Temp TS1..4 ≥ OTC:Threshold AND Charging for OTC:Delay duration | SafetyAlert()[OTC] = 0 SafetyStatus()[OTC] = 1 BatteryStatus()[OTA] = 1 BatteryStatus()[TCA] = 0 OperationStatus()[XCHG] = 1 if FET Options[OTFET] = 1 |
Recovery | SafetyStatus()[OTC] AND Max Cell Temp TS1..4 ≤ OTC:Recovery | SafetyStatus()[OTC] = 0 BatteryStatus()[OTA] = 0 BatteryStatus()[TCA] = 0 OperationStatus()[XCHG] = 0 |