SLUUCP8 June 2024 BQ41Z50
The BQ41Z50 device can detect overtemperature using a negative temperature coefficient (NTC) resistor connected to TS3 pin.
If the temperature from TS3 pin is over AFE:Over Temperature longer than AFE:Over Temperature Delay, the CHG and DSG FETs are turned off, and the pack is disabled permanently. For manufacturer testing, the fault state can be reset by a full power cycle of the device.
To enable this feature, the Settings.Permanent Failure.Enabled PF C.NTC should be set.
Status | Condition | Action |
---|---|---|
Normal | Temperature from TS3 pin lower than AFE:Over Temperature | PFStatus()[NTC] = 0 |
Trip | Temperature from TS3 pin is over AFE:Over Temperature longer than AFE:Over Temperature Delay | PFStatus()[NTC]
= 1 FUSE = high BatteryStatus()[TCA] = 1 BatteryStatus()[TDA] = 1 |