SLUUCP8 June 2024 BQ41Z50
The BQ41Z50 device can permanently disable the battery pack in case one of the cells in the stack is cell-balanced much more than the others.
Status | Condition | Action |
---|---|---|
Normal | Δ(CB Time Cell 1..4) < CB:Delta Threshold | PFAlert()[CB] = 0 |
Alert | Δ(CB Time Cell 1..4) ≥ CB:Delta Threshold | PFAlert()[CB] = 1 |
Trip | Δ(CB Time Cell 1..4) ≥ CB:Delta Threshold for CB:Delay(1) cycles | PFAlert()[CB] = 0 PFStatus()[CB] = 1 BatteryStatus()[TCA] = 1 BatteryStatus()[TDA] = 1 |
Trip | Max (CB Time Cell 1..4) ≥ CB:Max Threshold | PFAlert()[CB] = 0 PFStatus()[CB] = 1 |