SLUUCR6 December 2022
In order for this EVM to operate properly, the following components must be connected and properly configured.
Set input power supply to 5 V and Battery Simulator to 3.6 V with compliance to support 800 mA. Turn off Supply and Battery Simulator.
Connect input voltages to J1 and Battery Simulator to J2 on the EVM.
Configure all EVM jumpers to factory setting, refer to table below.
Turn on all supplies and loads
5-V Input supply current limit should be greater than 500 mA
Out voltage should be 3.6 V and charge current 400 mA
LED D1 and D2 will be ON
Simulate battery completing charge by increasing Battery Simulator voltage to 4.2 V
Current will decrease to 0 mA
LED D2 will switch to OFF.
I/O Connector | Factory Setting |
---|---|
JP1 |
Installed |
JP2 | IN |
JP3 |
Installed |
JP4 |
Fixed |
JP5 |
Installed |
JP6 | Fixed |
JP7 |
N/A |
JP8 |
N/A |
JP9 |
N/A |
S1 | Position 5 (4.2-V Li-Ion) |
S2 |
N/A |