Equipment - Using a CV Load

The following list of equipment is recommended when testing with a constant voltage electronic load.

  1. Power Supplies:

    A power supply capable of supplying 40V at 8A is required. While this part can handle larger voltage and current, larger power levels are not necessary for this procedure.

  2. Load #1:

    Kikusui PLZ164WA 0-150V, 0-33A, or equivalent. When testing without a real battery, connect 2000µF of capacitance across the input.

  3. Meters:

    Six Fluke 75 multimeters, (equivalent or better) or: Three equivalent voltage meters and three equivalent current meters.

  4. Computer:

    A computer with at least one USB port and a USB cable.

  5. EV2400 Communication Kit:
  6. Software: