SLUUCU8 july 2023
Table 3-2 lists the LM74912Q1EVM evaluation board input and output connector functionality. Table 3-3 and Table 3-4 describe the test point availability and the jumper functionality.
Connector | Label | Description |
---|---|---|
J1 | VIN | Power input connector to the positive rail of the input power supply. |
J3 | PGND | Ground connection for the power supply. |
J2 | VOUT | Power output connector to the positive side of the load. |
J9 | VOUT_LC | Power output connector after the output CLC Filter. |
J4 | PGND | Ground connection for the load. |
Test Points | Label | Description |
---|---|---|
TP1 | VIN | Input power supply to the EVM. |
TP2 | VOUT | Output from the EVM. |
TP3, TP4, TP14 | PGND | EVM ground. |
TP5 | EN | Enable input. |
TP6 | VS | Input power supply to the IC. |
TP7 | DGATE | Diode controller gate drive output. |
TP8 | HGATE | GATE driver output for the HSFET. |
TP9 | FLT/ | Active low open drain fault output. |
TP10 | SLEEP/ | Active low SLEEP mode input. |
TP13 | C | Cathode of the ideal diode. |
Jumper | Connection | Description |
---|---|---|
J5 | 1-2 | EN connected to C. EN pulled High |
2-3 | EN connected to GND. EN pulled Low | |
J6 | 1-2 | SLEEP/ connected to C. SLEEP mode disabled |
2-3 | SLEEP/ connected to GND. SLEEP mode active | |
J7 | 1-2 | Output high D5 LED indication |
J8 | 1-2 | SLEEP_OV connected to VOUT. Overvoltage clamp functionality in SLEEP mode |
2-3 | SLEEP_OV connected to C. Overvoltage cut-off functionality in SLEEP mode | |
J13 | 1-2 | FLT/ external voltage pullup |
3-4 |
FLT/ pullup to C |