Equipment

This section includes a list of supplies required to perform tests on this EVM

  1. Two Power Supplies: Keithley 2400 Powersupply or equivalent
    1. Power Supply #1 (PS #1) will be used as input voltage
    2. Power Supply #2 (PS #2) will be used as battery voltage
  2. 4 Channel Oscilloscope: To monitor voltages at VIN, VBAT, VSYS and BUCK
    1. Channel 1 (SC #1) will be used to probe VIN
    2. Channel 2 (SC #2) will be used to probe VBAT
    3. Channel 3 (SC #3) will be used to probe VSYS
    4. Channel 4 (SC #4) will be used to probe BUCK

  3. Computer: A computer with at least one USB port and a USB cable
  4. PC communication interface: USB2ANY with the latest firmware
  5. Software: Download the TI Charger GUI from Texas Instruments.