SLUUCY8 December 2023 BQ77307
Class | Subclass | Name | Type | Min | Max | Default | Unit |
---|---|---|---|---|---|---|---|
Protections | Temperature | Overtemperature in Charge Protection Recovery | U1 | 0 | 255 | 63 | VREG18 / 359 |
Description: This parameter configures the recovery threshold for the Overtemperature in Charge Protection. The protection recovers when the TS pin voltage is detected above this threshold.
This sets the threshold detected at the TS pin from 0 to 255 in units of VREG18 / 359.