BQ25308EVM is configured by default to operate with TS in normal range. If external thermistor is available, connect external thermistor at J1(2)-EXT_TS and J1(1)-PGND, and remove R14.
The leads and cables to the various power supplies,
batteries and loads have resistance. The current meters also have series resistance. The
charger dynamically reduces charge current depending on the voltage sensed at the VBUS pin
(using the VINDPM feature), BAT pin (as part of normal termination), and TS pin (through
the battery temperature monitoring feature via battery thermistor). Therefore, voltmeters
must be used to measure the voltage as close to the IC pins as possible instead of relying
on the digital readouts of the power supply.
When using a source meter that can source and sink
current as your battery simulator, TI highly recommends adding a large (1000+ μF)
capacitor at the EVM BATTERY and GND connectors to simulate a real battery. Configuring
the source meter for 4-wire sensing eliminates the need for a separate voltmeter to
measure the voltage at the BAT pin. When using 4-wire
sensing, always make sure that the sensing leads are connected to prevent accidental
overvoltage by the power leads.