Cell Simulator: Install a jumper for the series cell needed.
For instance, if 3S configuration is needed. See Figure 2-4.
Install these jumpers for thermistors as needed.
DFETOFF and CFETOFF are intended to be left floating unless user wants to manually turn off the FETs.
If RST_SD switch is installed, do not press the button for more than 5 seconds. This action can cause device to permanently lock up on initial units. See Figure 2-5.
Installing a jumper here means the device constantly wakes up, preventing entry to shutdown mode.
Enables the output of secondary protector (U14). U14 is not installed on board in version BMS081-E1.
For SPI, connect jumper as shown below. For SDK, please connect in the lower two. See Figure 2-6.
Install jumper when using J-link.
Upper two are for UART. Lower two are for J-link.
I2C pull-ps. These are not needed if using EV2400. EV2400 has integrated pull-ups.
Needed for Device power-up. Keep the jumper installed. The jumper is useful for measuring power consumption.
Do not install this jumper while flashing the device.
All of these jumpers are needed to determine series or parallel FET configuration. See Figure 2-7 and Figure 2-8.
Used to determines Series or Parallel FET configuration. See Figure 2-9 and Figure 2-10.