SLVA469D June 2013 – January 2023 TLV62130 , TLV62130A , TLV62150 , TLV62150A , TPS61175 , TPS61175-Q1 , TPS62130 , TPS62130A , TPS62131 , TPS62132 , TPS62133 , TPS62135 , TPS62136 , TPS62140 , TPS62140A , TPS62141 , TPS62142 , TPS62143 , TPS62150 , TPS62150A , TPS62151 , TPS62152 , TPS62153 , TPS62160 , TPS62161 , TPS62162 , TPS62163 , TPS62170 , TPS62171 , TPS62172 , TPS62173
The inductor and output capacitor must both be selected based on the needs of the application and the stability criteria of the device, which are different from the traditional buck converter approach. A load transient test should be performed to evaluate stability. Figure 4-9 shows the results of such a test performed on the example circuit. The lack of ringing indicates stability.