SLVK120A may   2023  – may 2023 TPS7H1111-SP

PRODUCTION DATA  

  1.   1
  2.   TPS7H1111-SP Neutron Displacement Damage Characterization
  3.   Trademarks
  4. 1Overview
  5. 2Test Procedures
  6. 3Facility
  7. 4Results
  8. 5Data Sheet Electrical Parameters and Associated Tests
  9.   A Appendix: Test Results
  10.   B Revision History

Test Procedures

The TPS7H1111-SP was electrically pre and post-tested using the production automated test equipment program.

General test procedures adhered to MIL-STD-883, Method 1017 for Neutron Irradiation of TPS7H1111-SP. Neutron irradiation conditions are listed in Table 2-1.

Table 2-1 Neutron Irradiation Conditions
GROUPSAMPLE QTYNEUTRON FLUENCE (n/cm2)BIAS
A31.0 × 1012Unbiased
B35.0 × 1012Unbiased
C31.0 × 1013Unbiased
GUID-20230426-SS0I-GLZN-R4BV-NRCJMV871GHW-low.jpgFigure 2-1 TPS7H1111-SP Device (Front)