Test Configuration and Condition

HDR devices were stressed up to 100 krad(Si) for biased and unbiased conditions.

Table 2-2 HDR Biased Device Information
Total Samples: 25 units + 1 control
Exposure Levels:
3 krad(Si) 10 krad(Si) 30 krad(Si) 50 krad(Si) 100 krad(Si)
134, 137, 138, 139, 236 237, 241, 242, 243, 244 132, 133, 135, 245, 246 172, 173, 174, 183, 186 178, 179, 180, 181, 182
Table 2-3 HDR Unbiased Device Information
Total Samples: 25 units + 1 control
Exposure Levels:
3 krad(Si) 10 krad(Si) 30 krad(Si) 50 krad(Si) 100 krad(Si)
58, 59, 60, 61, 62 63, 64, 65, 66, 150 141, 144, 145, 146, 147 67, 68, 69, 71, 72 95, 102, 104, 105, 106