SLVK176 August 2024 TPS7H5003-SP
This report discusses the results of the total ionizing dose (TID) testing for TPS7H5003-SP QMLP, Texas Instruments 4-V to 14-V radiation-tolerant, current mode, single output PWM controller optimized for DC-DC converters in space applications. The study was done to determine TID effects under high dose rate (HDR) up to 100 krad(Si). The results show that all samples passed within the specified limits up to 100 krad(Si).