SLVK176 August 2024 TPS7H5003-SP
HDR devices were stressed at 3krad(Si), 10krad(Si), 30krad(Si), 50krad(Si), and 100krad(Si) for biased and unbiased conditions.
Total Samples: 25 | ||||
---|---|---|---|---|
Exposure Levels | ||||
3 krad(Si) | 10 krad(Si) | 30 krad(Si) | 50 krad(Si) | 100 krad(Si) |
770, 331, 279, 694, 337 | 209, 720, 327, 700, 851 | 119, 90, 297, 594, 586 | 301, 593, 374, 650, 324 | 265, 482, 372, 308, 438 |
Total Samples: 25 | ||||
---|---|---|---|---|
Exposure Levels | ||||
3 krad(Si) | 10 krad(Si) | 30 krad(Si) | 50 krad(Si) | 100 krad(Si) |
717, 685, 360, 427, 785 | 498, 139, 632, 465, 500 | 571, 172, 375, 445, 103 | 152, 359, 126, 883, 117 | 562, 753, 547, 724, 534 |