SLVK177 August   2024 TPS7H5004-SP

 

  1.   1
  2.   2
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Condition
  6. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 Specification Compliance Matrix
  7. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  8.   A Appendix: Specifications Requiring Clarification
  9.   B Appendix: HDR TID Report Data

Test Configuration and Condition

HDR devices were stressed at 3krad(Si), 10krad(Si), 30krad(Si), 50krad(Si), and 100krad(Si) for biased and unbiased conditions.

Table 2-1 HDR: 3-krad(Si) to 100-krad(Si)/s Biased Device Information
Total Samples: 25
Exposure Levels
3krad(Si)10krad(Si)30krad(Si)50krad(Si)100krad(Si)
442, 699, 344, 355, 750

540, 387, 787, 1042, 483

538, 164, 1018, 462, 1032795, 921, 741, 809, 8041036, 1038, 203, 1029, 1027
Table 2-2 HDR: 3-krad(Si) to 100-krad(Si)/s Unbiased Device Information
Total Samples: 25
Exposure Levels
3krad(Si)10krad(Si)30krad(Si)50krad(Si)100krad(Si)

689, 688, 700, 482, 1033

537, 396, 521, 535, 526

597, 853, 416, 949, 221566, 197, 793, 802, 61449, 541, 476, 45, 642