SLVK178 September   2024 TPS7H1121-SP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Conditions
  6. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 TPS7H1121-SP Data Sheet Electrical Parameters
  7. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  8.   A Appendix: HDR TID Report Data

Device Details

Table 1-1 lists the device information used in the TID HDR characterization.

Table 1-1 Device and Exposure Details
TID HDR Details: Up to 100krad(Si)
TI Device NumberTPS7H1121-SP (5962R2320301VXC)
Package22 PIN HFT
TechnologyLinear BiCMOS 7 (LBC7)
Die Lot Number3300911
A/T Lot Number / Date Code4002887MTT / 2424A
Quantity TestedHDR: 50 Devices
  • Five biased and five unbiased units at 3krad (Si) levels
  • Five biased and five unbiased units at 10krad (Si) levels
  • Five biased and five unbiased units at 30krad (Si) levels
  • Five biased and five unbiased units at 50krad (Si) levels
  • Five biased and five unbiased units at 100krad (Si) levels
  • Seven control/correlation units with no exposure
HDR Radiation FacilityDCLAB - Texas Instruments, Dallas, TX
HDR Dose Level100krad (Si)
HDR Dose Rate174.936 rad (Si)/ s ionizing radiation dose rate
HDR Radiation SourceGammacell 220 Excel (GC-220E) Co-60
Irradiation TemperatureAmbient, room temperature
 Device Used in
                        ExposureFigure 1-1 Device Used in Exposure