SLVS984B
September 2009 – March 2015
TPS22946
PRODUCTION DATA.
1
Features
2
Applications
3
Description
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Electrical Characteristics
6.6
Switching Characteristics
6.7
Typical Characteristics
7
Parameter Measurement Information
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Detection Schemes
8.3.1.1
Overtemperature Detection
8.3.1.2
Hard-Short Detection
8.3.1.3
Moderate Overcurrent Detection
8.3.1.4
Current Limiting Mode
8.3.1.5
Fault Reporting
8.3.1.6
Power-On and Power-Off Sequence
8.3.1.7
Automatic Disable in Case of Permanent Overcurrent
8.3.2
Inrush Current Time-out Feature
8.3.3
CL Control Pin
8.3.4
Overtemperature Protection
8.4
Device Functional Modes
9
Application and Implementation
9.1
Application Information
9.1.1
On/Off Control
9.2
Typical Application
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.3
Application Curve
10
Power Supply Recommendations
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Trademarks
12.2
Electrostatic Discharge Caution
12.3
Glossary
13
Mechanical, Packaging, and Orderable Information
11 Layout
11.1 Layout Guidelines
The C
IN
capacitor should be placed as close as possible to the V
IN
pin.
The V
IN
and V
OUT
traces should be the appropriate width to carry the load current.
The CL pin may be connected directly the GND or VIN (depending on the desired current limit). The CL pin may also be left floating.
11.2 Layout Example
Figure 36. Layout Example