SLVSAA4G June 2010 – February 2018 TPS65251
PRODUCTION DATA.
To select the internal switching frequency connect a resistor from ROSC to ground. Figure 15 shows the required resistance for a given switching frequency.
For operation at 800 kHz a 230-kΩ resistor is required.