SLVSDR3C may 2018 – may 2023 ADC12DL3200
PRODUCTION DATA
Input full-scale voltage (VFS) adjustment is available, in fine increments, for each analog input through the FS_RANGE_A (see the INA full-scale range adjust register) and FS_RANGE_B register settings (see the INB full-scale range adjust register) for INA± and INB±, respectively. The available adjustment range is specified in the Section 6.5 table. Larger full-scale voltages improve SNR performance, but can degrade harmonic distortion. The full-scale voltage adjustment is useful for matching the full-scale range of multiple ADCs when developing a multi-converter system or for external interleaving of multiple ADC12DL3200s to achieve higher sampling rates.