SLVSDV7C February 2018 – February 2020 TPS2HB16-Q1
PRODUCTION DATA.
PIN | I/O | DESCRIPTION | ||
---|---|---|---|---|
NO. | Version A/B | Version F | ||
GND | 1 | 1 | - | Device ground |
SNS | 2 | 2 | O | Sense output |
LATCH | 3 | 3 | I | Sets fault handling behavior (latched or auto-retry) |
EN1 | 4 | 4 | I | Channel 1 control input, active high |
ILIM1 | 5 | - | O | Connect pull-up resistor to VBB to set current-limit threshold on CH1 |
FLT1 | - | 5 | O | Open drain fault indication |
VOUT1 | 6-8 | 6-8 | O | Channel 1 output |
VOUT2 | 9-11 | 9-11 | O | Channel 2 output |
ILIM2 | 12 | - | O | Connect pull-up resistor to VBB to set current-limit threshold on CH2 |
FLT2 | - | 12 | O | Open drain fault indication |
EN2 | 13 | 13 | I | Channel 2 control input, active high |
SEL1 | 14 | 14 | I | Diagnostics select 1. No functionality on version F; tie to device ground through 10 kΩ resistor |
SEL2 | 15 | 15 | I | Diagnostics select 2 |
DIA_EN | 16 | 16 | I | Diagnostic enable, active high |
VBB | Exposed Pad | Exposed Pad | I | Power supply input |