SLVSEJ2A February 2018 – April 2018 TPSM84424
PRODUCTION DATA.
The internal thermal shutdown circuitry forces the device to stop switching if the junction temperature exceeds 170°C typically. The device reinitiates the power up sequence when the junction temperature drops below 155°C typically.