SLVSEK5A August 2018 – October 2018 TPS7B70-Q1
PRODUCTION DATA.
Set the power-good delay with an external capacitor (CDELAY) to ground. Calculate the correct capacitance with Equation 2. This application requires a delay of 20 ms, so solve for the correct capacitance required to get this delay. As shown in Equation 4, rearrange Equation 2 to solve for CDELAY.