SLVSFQ0B October 2020 – June 2024 TPS54J061
PRODUCTION DATA
The device has a fixed, cycle-by-cycle negative current limit. Similar with the positive overcurrent limit, the inductor current is monitored during the OFF state. To prevent too large negative current flowing through low-side FET, when the low-side FET detects –3.5-A current (typical threshold), the device turns off the low-side FET and turns on the high-side FET for the on-time determined by VIN, VOUT, and fSW. After the high-side FET on-time expires, the low-side FET turns on again.