Prior to connecting the DC input source
VIN, it is advisable to limit the source current from VIN to 10 A
maximum. Ensure that VIN is initially set to 0 V and connected as shown in
Figure 4-2.
Connect a voltmeter V1 at TP6 (VIN) and TP7
(PGND) to measure the input voltage.
Connect a current meter A1 to measure the input current.