SLVU356A January 2010 – October 2021 TPS54290 , TPS54291
VIN to J1
The connection between the source voltage, VIN, and J1
of HPA431 can carry as much as 5 Adc. The minimum recommended wire size is AWG #16
with the total length of wire less than four feet (two feet input, two feet
return).
J2 to LOAD1
The power connection between J2 of HPA431 and LOAD1 can carry as much as 1.5 Adc.
The minimum recommended wire size is AWG #18 with the total length of wire less than
two feet (two foot output, two foot return).
J3 to LOAD2
The power connection between J3 of HPA431 and LOAD2 can carry as much as 2.5 Adc.
The minimum recommended wire size is AWG #18 with the total length of wire less than
2two feet (one foot output, one foot return).