SLVU392A July 2010 – January 2022 TPS53125
VVIN to J3 – The connection between the source voltage, VVIN, and J1 of thTPS53125EVM-599 can carry as much as 2 ADC. The minimum recommended wire size is AWG #16 with the total length of wire less than two feet (1-foot input, 1-foot return).
J1 to LOAD1 and J2 to LOAD2 – The connection between J1 and LOAD1 and J2 and LOAD2 of the TPS53125EVM-599 can carry as much as 4 ADC each. The minimum recommended wire size is AWG #14, with the total length of wire less than two feet (1-foot input, 1-foot return).