SLVUBX0A July 2021 – January 2022 TPSM8A28 , TPSM8A29
TP14 is the VCC test point for the internal LDO. It can be used to monitor the VCC voltage, or it can be used to override the internal LDO of the TPSM8A29 for higher efficiency. Frequently, systems will have an LDO present somewhere in the design which can be used here to reduce the power losses associated with producing a low-noise supply rail with a linear regulator. The internal LDO produces a typical voltage of 4.5 V, so the recommended input range for an external bias on the VCC pin is 4.75 V to 5.3 V. Because of the limited sourcing current capability of the internal LDO, do not connect any external loading to this pin.