Use the following instructions to observe the Quick Output Discharge (QOD) functionality:
Set the input supply voltage VIN to-12 V and current limit to 10-A. Turn ON the power supply.
Use the switch SW1 to connect the EN/UVLO pin to ground to do power cycling.
Use the switch SW2 to enable the QOD by making the voltage at EN/UVLO pin in the range of 0.8-V to 1.1-V with the input voltage of 9.8-V to 13.5-V.
Observe the waveforms of VIN (TP3), VOUT (TP4), PG(TP32), and EN(TP33) using an oscilloscope.
In Figure 5-17, the turn-off performance of the TPS25985 eFuse with QOD enabled is shown, whereas Figure 5-18 illustrates the turn-off performance with QOD disabled on the TPS25985EVM eFuse Evaluation Board.
Figure 5-17 QOD Enabled on TPS25985 eFuse (VIN = 12 V, COUT = 470 µF, and EN Pulled Low to 0.8 V)
Figure 5-18 QOD Disabled on TPS25985 eFuse (VIN = 12 V, COUT = 470 µF, and EN Pulled Low to 0 V)