Use the following instructions to perform the overvoltage protection test:
Set the input supply voltage VIN to 12 V and current limit to 100 A. Apply the supply between VIN (Connector T1) and PGND (Connector T3) and enable the power supply.
Apply a load of 1.2 Ω between VOUT (Connector T2) and PGND (Connector T3).
Increase the input supply VIN from 12 V to 18 V and observe the waveforms using an oscilloscope.
Note: The input TVS diodes should be removed during the overvoltage protection test. Make sure to put them back after this experiment.
Figure 5-9 shows overvoltage lockout response of TPS25985 eFuse on TPS25985EVM eFuse Evaluation Board.
Figure 5-9 Overvoltage Lockout Response of TPS25985 eFuse (VIN Ramped Up from 12 V to 18 V, COUT = 470 μF, and RLOAD = 1.2 Ω)