Use the following instructions to perform the overcurrent test on the circuit breaker TPS259814 eFuse:
- Place jumper J10 to the appropriate position to obtain required blanking period as per Table 4-3.
- Set the input supply voltage VIN to 12 V and current limit of 12 A and enable the power supply.
- Place jumper J12 in suitable position to set the required current limit as per Table 4-3.
- Apply an overload greater than the set current limit between VOUT1 and GND.
- The device allows the overload current for the programmed ITIMER period and then switches OFF.
Figure 5-3 shows an example of the circuit breaker test on the TPS25981EVM.