SLVUCH5 july   2023 LMQ644A2-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1EVM Description
    1. 1.1 Features and Electrical Performance
  5. 2EVM Performance and Specifications
  6. 3EVM Photo
  7. 4Test Setup and Procedure
    1. 4.1 EVM Connections
    2. 4.2 Test Equipment
    3. 4.3 EVM Setup
      1. 4.3.1 Input Connections
      2. 4.3.2 Output Connections
  8. 5Test Data and Performance Curves
    1. 5.1 Efficiency and Load Regulation Performance
    2. 5.2 Waveforms and Plots
    3. 5.3 EMI Performance
    4. 5.4 Thermal Performance
  9. 6EVM Documentation
    1. 6.1 Schematic
    2. 6.2 Bill of Materials
    3. 6.3 PCB Layout
  10. 7Device and Documentation Support
    1. 7.1 Device Support
      1. 7.1.1 Development Support
        1. 7.1.1.1 Custom Design With WEBENCH® Tools
    2. 7.2 Documentation Support
      1. 7.2.1 Related Documentation

Output Connections

  • Connect voltmeter2 at VOUT1S+ and VOUT1S– sense points to measure the CH1 output voltage.
  • Connect voltmeter3 at VOUT2S+ and VOUT2S– sense points to measure the CH2 output voltage.
  • Connect load1 to the VOUT1+ and VOUT1– connections as shown in Figure 4-1. Set the load to constant-resistance mode or constant-current mode at 0 A before applying input voltage.
  • Connect load2 to the VOUT2+ and VOUT2– connections as shown in Figure 4-1. Set the load to constant-resistance mode or constant-current mode at 0 A before applying input voltage.