SLVUCK1 April 2024 TPS7H4011-SP
The TPS7H4011EVM-CVAL includes 8 jumpers to control SYNCM, SYNC2, FSW, RSC, and ILIM. In order for the device to switch properly without an external clock signal, a jumper must be installed in J7 (FSW_SEL). It is also recommended that a jumper be installed in J6 (RSC_SEL) whenever the device is operating for slope compensation to function. The proper slope compensation depends on the exact device configuration. Please see the TPS7H4011-SP data sheet for more information.
The TPS7H4011EVM-CVAL provides 4 jumpers for setting the device's current limit (ILIM). When setting a current limit with the jumpers, please ensure only one current limit jumper is populated at a time for a proper current limit configuration. It is recommend to have an ILIM jumper populated whenever the device is functioning.