SLVUCO4 October 2023 TPS62916
For applications which do not require the lowest output voltage ripple, the TPS62916 can be operated without the second LC filter. To operate with a single LC filter, replace FB1 with a 0-Ω resistor. The total output capacitance must remain within the recommended range in the data sheet for proper operation.