SLVUCT4 November 2023
Jumper | Description |
---|---|
J1 | Input voltage positive connection |
J2 | Output voltage positive connection |
J3 | Input voltage return connection |
J4 | Output voltage return connection |
J5 | EN pin input jumper. Place a jumper across EN and H to turn on the IC. Place a jumper across EN and L to turn off the IC. |
J6 | MODE pin input jumper. Place a jumper across MODE and H to set the device in forced PWM mode. Put the jumper across MODE and L to set the device in auto PFM mode. |
TP1 | Input voltage positive sensing node for measuring efficiency |
TP2 | Output voltage positive sensing node for measuring efficiency |
TP3 | Input voltage negative sensing node for measuring efficiency |
TP4 | Output voltage negative sensing node for measuring efficiency |
TP5 | Test point to measure bode plot |
TP6 (SW) | Test point to measure SW pin waveform |