Prior to connecting the DC input source, set the
current limit of the input supply to 0.1A maximum. Make sure the input source is
initially set to 0V and connected to the VIN+ and VIN– connection points as
shown in Figure 2-1.
Connect voltmeter 1 at VIN_S and PGND (TP3)
connection points to measure the input voltage.
Connect ammeter 1 to measure the input current
and set the ammeter to at least a 0.1 second aperture time.